Circupool flow switch. Asked 2 ´years ago.
Circupool flow switch Asked 8 ´months ago | Sanitation > Salt Chlorinators > RJ When the red No Flow light is on in your CircuPool SJA Series salt chlorinator, despite the clear housing being full and strong water flow, you should first ensure the salinity level is within the suggested range. If you are able to apply power to the CM without the pump operating, then power it on and hold the flow switch closed. Can the control unit stay outdoors during the winter View answer. The Flow LED on the panel will turn green for aprox. I bought Sj20a because it said it was for 20,000 gallon. Buy it Now Featured Products (122) CircuPool® SJ-20 Salt To send a CircuPool Edge salt cell in for inspection, do you send the entire cell including housing or can the blades be removed and sent? View answer. Estimated Delivery Times. With water flow holding the leg open that already stays open or against the water flow causing the leg to stay down. Other than that, the pump speeds do not affect If your CircuPool RJ Plus Series salt chlorine generator consistently reads the temperature as 77 degrees, this may indicate that the internal 'jumper' is set to draw temperature data from the flow switch, which defaults to 77F with an ordinary flow switch. ) Always make sure that input power is completely disconnected before attempting service or troubleshooting procedures. Asked This video guide goes over the essential steps involved during the installation of the CircuPool RJ-Series. 90. Generally speaking, any pump needs to "turnover" all the water through the pool through the filter 1. What does SLO mean? View answer. Housing for the flow switch and temperature sensor for CircuPool EDGE models only. We'd love to hear from you. Asked 10 ´months ago | Sanitation > Salt Chlorinators > Universal Series > CircuPool Universal Series Salt Chlorine Generators - Owner Resources. The CircuPool SJ Classic Series Salt Chlorinators were specifically engineered without the inclusion of a flow switch. If it does not, you will need a new flow switch. Support. In other words, do not put the flow switch too close to a 90 or 45 degree elbow. Jul 20, 2022 - 12:00 AM. is cable Genuine CircuPool titanium salt cells for easy replacement once your old salt system's cell has worn out. View Details Add To Cart (10) CircuPool® RJ Keypad (3rd Gen, RJNK15) $58. View Details Select Options. Install new flow switch and twist it clockwise to Flow Switch Question View answer Asked 5 ´months ago | Sanitation > Salt Chlorinators > SJ Series > CircuPool SJ-A Series Salt Chlorine Generators - Owner Resources Why won't my SJ20 cycle the reverse polarity. 2 min. works great. Activity timeframe - Apply filters ; Questions ; Most Popular Recently Asked Recently Active. Is this the one I need? View answer. Disconnect the flow switch wire from the RJ control box. If your pool Asked 2 ´years ago | CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) Can I get terminal block jumpers to change from 240 to 120 View answer. View all Q&A. This flow switch is replaced simply by screwing it into place after unscrewing the existing With the CircuPool SJ-A Series of Salt Chlorinators, you can't bypass the Flow Switch. View Details Add To Cart (14) CircuPool® Flow Switch / Temperature This video guide goes over the essential steps involved during the installation of the CircuPool SJ-Series. Flow Switch & Temperature Sensor: This component ensures that there is adequate water flow for the Cell to activate. Remember that your pool is compatible with chlor IMPORTANT: ine and shock as normal. Part Number: SJA-FS. The RJ PLUS Series will illuminate the Which direction does the flow switch face. If these steps don't fix the issue, the CircuPool customer service team is CircuPool Help Guides: SJ-A Series (2 nd Gen. Asked 4 ´months ago | Support. Detailed instructions on how Flow Switch light is flashing CircuPool RJ-PLUS Series Salt Chlorine Generators - Owner Resources RJ PLUS Series Status: Open Aug 07, 2024 - 12:58 PM. Make sure the directional arrow is facing the same direction as the water flow. Ask your question here Home; Login; Register; Search What is the minimum GPM through 2" pipe to activate the flow switch on 25 model? CircuPool® Universal25 Salt Chlorine Generator Universal Series Status: Open Aug 24, 2023 - 01:50 PM. Learn; Cart 0; Standard Flow Switch, fits Hayward Aqua Rite, CircuPool How to Install the Temperature Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. Furthermore, there are no existing provisions to facilitate the addition of one. 36A at 220V. Reinstall flow switch into PVC T-fitting (Housing). the new SJ-35 Gen 2 has a flow switch. Circupool SJA flow sensor compatibility View answer. Either way, give our support team a call and we'll be happy to help you find the best solution: 888-206-9938x2. It is only compatible with 1. A: Yes, it is "plug-and-play" to upgrade to the larger cell size. 00 . Browse by Category. Asked 2 ´years ago. • Remote: The part is controlled by a remote control system. May 11, 2023 - 11:45 AM. Standard shipping was about $10 and 3-4 weeks delivery. Possible fix? View answer. Asked 15 ´days Flow switch works, cell is clean, just had RJ45+ unit serviced and returned 5-6 months ago. 8 amps. <!--I run at 2500 rpm for 2 hours, 1000 rpm for 10 hours, and 800 rpm for 12 hours. Generic Flow Switch (with Temperature Sensor) - PVC Tee Fitting Not Included-Standard Flow Switch, fits Hayward Aqua Rite, CircuPool Si/Universal, Cir. To fix this, you begin by rerouting the temperature reading from the cell to the flow switch by moving a "jumper" inside the control module. Asked 3 ´years ago. Will it still generate chlorine with a high salt reading? View answer. I am re-plumbing My RJ60+ because of leaks. How to Set the Temperature Reading Source for the Temperature Flow Switch WARNING If a flow switch is replaced by a “temperature / flow switch”, follow these instructions to allow the electronics to take temperature readings from the sensor in the new temperature / flow switch. Additional Troubleshooting (turn off pump and salt system): • Unscrew the Flow Sensor from the PVC tee-fitting. CircuPool SJA Flow Switch (without PVC T-Fitting) Q&A. Simple unscrewed the flow switch from the Tee fitting and installed the switch into the The CircuPool EDGE25 replacement salt cell is the genuine, factory-authorized replacement designed exclusively for CircuPool EDGE25 salt chlorine generator systems for pools up to 25,000 gallons. Control Module: This component supplies power to the cell and allows you to customize the system's operation in order to meet your pool's Specifications: Voltage: 110V Watt: 180 Indicators: Power, Generating, Super Chlorine, Remote, No Flow, Check Salt, High Salt and Inspect Cell Adjustable Chlorine Outlet: Yes Chlorine Output: 30 grams/hour Cell Self Cleaning: Reverse Polarity Pool Size Rating: 25,000 Gallons Ideal Salt Level: Between 3200 ppm and 4000 ppm Salt Cell Size: 13-1/2"(L) x 4"(W) x 5"(H) Control Box Browse CircuPool® Universal25 Salt Chlorine Generator questions and answers, or ask your own CircuPool® Universal25 Salt Chlorine Generator question and receive a knowledgable answer from a topic expert. Manual is suitable for 5 CircuPool Help Guides: Universal / S i Series Always make sure that input power is completely disconnected before attempting service or troubleshooting procedures. 5 and 7. 3 5 0 5 FAQ 0. Do you have the The CircuPool SJ35 uses advanced titanium electrolytic cells to effortlessly and automatically maintain sparkling blue water for a luxurious swimming experience. 3. Turn off the pump. CircuPool EDGE Flow/Temperature Sensor PVC T-Fitting. The Flow Switch is an safety device that ensures water is flowing before Dec 13, 2022 · Reinstall flow switch into PVC T-fitting (Housing). Refer to your manual for important installation instructions and warnings. View Details Add To Cart. Page 19: Maintenance General Maintenance To maintain maximum performance, it is recommended that you remove and visually inspect the cell at least every 3-4 months. CircuPool RJ-PLUS Series Salt Chlorine Generators Only the flow switch has a direction that it must strictly face. 3 SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS. This guide will help visualize the steps of plumb The EDGE-25's switch-mode power supply can also automatically accept 110V or 220V, making it easy to connect to an existing pump timer or controller CircuPool EDGE models are Made In America. Asked 7 ´months ago | Sanitation > Salt If you have an older SJ Classic model, it is not able to utilize a flow switch. View More Product Details. Yes, all of the CircuPool RJ Series chlorine generators come with a flow switch! 0. The Flow Switch is an safety device that ensures 3 days ago · This Genuine CircuPool® Flow Switch easily reconnects to your existing electrical and plumbing fittings. 5 inch plumbing. • No Flow: This LED is illuminated when the Flow Switch has detected no flow. This model is dual-voltage (automatically converting either 240VAC or What is the total dimension for the flow switch and cell for the Edge 40? 11 3/4 inches CircuPool® Classic Combo (Salt Chlorinator + Pump) EDGE Series Status: Open Jan 30, 2020 - 12:00 AM Do you have the same question? Would this flow meter work in a 305 px natural chlorine generator? It looks exactly the same as the one I'm replacing. Turn equipment back on and wait 3 minutes to give the equipment time to detect flow. Available in three different model sizes, the affordable For salt chlorinators in general, and certainly the CircuPool SJ-A series, the initial start up can yield flashing or changing Flow light until the water flow stabilizes and, along with it, the light. CircuPool SJA Flow Switch. Learn how to get the most out of your RJ-Series Salt System View Details. View Details Add To Cart (3) CircuPool® Threaded Cell Collar - RJ (3rd-Generation) $3. Will it still CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) CircuPool® Flow Switch Housing; CircuPool® Flow Switch with 15' Cable (No Tee Fitting) CircuPool® INDIGO3 Replacement Lamp for Pool Ozone Generators; CircuPool® INDIGO3-M Ozone Generator for Swimming Pools; CircuPool® INDIGO3-S Ozone Generator for Swimming Pools Asked 2 ´years ago | CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) Does this work with a CircuPool RJ30+ View answer. No PVC T-Fitting is included. Comments (0) | New CircuPool SJA Flow Switch Housing Only-Replacement PVC housing for flow switch for CircuPool SJA models only. Asked 8 ´months ago | Support. The new 2rd-generation SJ20 features digital power supply, streamlined controls, and independent flow switch. Contact technical support for details. High chlorine demand is a common issue in pools, and this guide will help you 1) verify your system is working normally, and 2) identify & fix common causes that require greater amounts of chlorination. Result 23 hours ago · Choose genuine factory replacement parts for your CircuPool salt chlorinator system. Ensure all owners / operators of this equipment have access to these instructions. When the generator has power and the pump is operating, the flow switch will automatically control chlorine generation. Nov 10, 2022 - 07:05 AM . Comments (0) | New Comment Absolutely, the CircuPool RJ PLUS Series of Salt Chlorinators, including the RJ-45 PLUS model, provides the flexibility to install the flow switch in a vertical position, either before or after the salt cell, based on your specific requirements. Asked 3 ´years ago . Does Browse CircuPool® RJ-60 PLUS Salt Chlorine Generator questions and answers, or ask your own CircuPool® RJ-60 PLUS Salt Chlorine Generator question and receive a knowledgable answer from a topic expert. I just had a variable speed pool pump installed. Asked 8 ´months ago. 0. If deemed necessary, the flow switch of a CircuPool Universal Series Salt Chlorinator can be strategically installed after the salt cell. Warranty Guide . So, no it can't go between the heater and filter. Aug 01, 2022 - 12:00 AM. View answer . I have the RJ45 unit with 1. Answer. 10 seconds and then go red for aprox. Bear in mind, too, that a solid, red light is an indication that you are not generating chlorine. Asked 1 ´year ago | Replacement Parts > Parts & Accessories > Si / Universal Models. Genuine replacement lamps for easy replacement once your ozone generator's lamp has been worn out. Answer . Si / Universal Models. This message indicates a failure in the temperature sensor. However, the manual also mentions the cell current ranging between 2. This manual is also suitable for: Oct 22, 2024 · How to Install the Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. CircuPool® Replacement Union - SJA Models. If the flow switch doesn't get triggered, it simply deactivates the system until normal flow resumes. This model is dual-voltage (automatically converting either 240VAC or Electrolytic Cell and Flow Switch Connections: The Cell and Flow Switch cables have easy plug-in connectors, which attach easily to the Control Module. Asked 1 ´year ago. 74. If you have a newer SJ-A model and you need a replacement flow switch, we can help you with that. Then, verify the cell's connection to the control module per the guidelines attached. Comments (0) | New Comment View More I have a SJ-series system 4 years ago. How to Install the Temperature Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. Universal Warranty Information; Common Questions. If the flow switch tests bad, call us to replace it under warranty. It goes threw its own internal timers. This advanced titanium cell ensures optimal performance and seamless integration with your existing EDGE25 system, perfect fit guaranteed. RJ-PLUS Warranty Information; Common Questions. To prevent the unit from operating whenever the pump runs, reconnect your SJ-A to a timer and control its operation via the timer. Additional Items Required (Not Included) Control Module Electrolytic Cell Flow Switch PVC Cement, PVC Primer, Hacksaw or Pipe Cutters, Screwdrivers, Permanent Marker Need a temperature flow switch CircuPool Universal Series Salt Chlorine Generators - Owner Resources RJ PLUS Series. View Details Add To Cart (6) CircuPool® Replacement Union - Universal / Si Models. First, however, we recommend that you check this troubleshooting guide at the link below. Easily replaces Hayward salt systems, from 5000 - 40000 gallons as a drop-in replacement. My current pool equipment configuration does not include a flow switch. In these instances, look carefully on, and around, the flow switch to see if there is any marking to indicate a specific direction for the waterflow. CircuPool Threaded Cell Collar - EDGE . With respect to the recommendations for straight pipe ahead of the switch, it is important to meet the recommendations if at all possible, but Inactive unit, flow switch not triggered Inspect Flow Switch, verify sufficient water flow Inactive unit, power is off Turn on system, or see “No Power” Low or no Chlorine residual in pool after recent installation Water chemistry was not balanced prior to system installation and a high chlorine demand persists Contact pool professional, ensure all chemicals on p. Ensure you get years more of value out of your existing equipment by using authentic CircuPool parts. Additional Items Required (Not Included) Control Module Electrolytic Cell Flow Switch PVC Cement, PVC Primer, Hacksaw or Pipe Cutters, Screwdrivers, Permanent Marker Inactive unit, flow switch not triggered Inspect Flow Switch, verify sufficient water flow Inactive unit, power is off Turn on system, or see “No Power” Low or no Chlorine residual in pool after recent installation Water chemistry was not balanced prior to system installation and a high chlorine demand persists Contact pool professional, ensure all chemicals on p. ), and more. Result (A): If you still see the "No flow" light the flow switch needs to be replaced. Circupool edge on for four days all the lights come on but chlorine still low have it on boost 24/7 View answer. CircuPool Help Guides: Universal / Si Series Install new flow switch and twist it clockwise to tighten. The internal flow switch is bi-directional, so the unit can be installed with either port as the inlet/outlet. Circupool wanted $79 for just the flow switch, and almost $60 for overnight delivery. Installation kit includes PVC fittings and pre-cut pipes needed for quick assembly for the following configurations: 1) standard set-up for new installations, 2) retrofit Most salt chlorinators typically need a small amount of flow in the 20-30 gpm range, but there are also other factors in you pool equipment set up that it depends on. There are three main components to your CircuPool RJ Series system: the Control Module, the Electrolytic Cell, and the Flow Switch. Install new flow switch and twist it clockwise to Pool owners love CircuPool RJ-PLUS Series salt systems, the #1 favorite to keep your swimming pool crystal clear without the hassle or expense of buying chlorine. With this style system, the flow switch may work in one direction only or function correctly in either direction. I originally bought a RJ-60 plus system. 5 - 2x per day. Temperature/Flow Switches are Included in the CircuPool RJ Plus Series kit, you will receive both 2” and 1. Could this be a faulty flow switch or something else? View answer If the flow switch is working, the no flow light should blink for around 60 seconds and then go out. The CircuPool® Flow Switch Housing is SKU: GFS-HSG and can be found at the link below. OK? Or am I going to have to re-plumb? Status: Open Mar 21, 2024 - 01:47 PM. Asked 1 ´year ago | Sanitation > Salt Chlorinators > SJ Series > CircuPool SJ-A Series Salt Chlorine Generators - Owner Resources. Status: Open Jun 07, 2021 - 12:00 AM. The new 2rd-generation SJ35 features digital power supply, streamlined controls, and independent flow switch. 23 hours ago · This CircuPool® Flow Switch and Temperature Sensor easily reconnects to your existing electrical and plumbing fittings. Product Q & A. Genuine replacement cartridges for CircuPool Cartidge Filters. However, make sure there is at least 6" of straight run PVC pipe before the water enters the flow switch. 40. Unplug the flow switch from the control module and re-install just to be sure it’s plugged in well and fully seated. This part is threaded into 2 . Filter . If the flow switch is working, the no flow light should blink for around 60 seconds and then go out. When it will go green again for 10 seconds repeating. Asked 8 ´months ago . CircuPool SJA Flow Switch Housing Only. Hello. How do you claim a warranty on my CircuPool equipment? View answer. does the SJ- series have a built in flow switch sensor built in. Just installed a new Circupool RJ60 no flow light is on View answer. Manufacturer 7 Year Limited Warranty for residential use. The integrated timer does not allow any external devices to be wired to it. $9. If your equipment comes on and off together, you will need to remove the flow switch from the line and tie it closed with a string or rubber band and then re-install it in order to test it. Additional Teflon tape can be added to the threads to ensure a tight water seal. Ask a Question. EDGE Warranty Information; Common Questions. You can also adjust output in 5% If replumbing is required, a new tee by itself can be added to the plumbing, and the existing flow switch can be unscrewed from its old fitting and re-used. Install new flow switch and twist it clockwise to CircuPool offers cutting-edge complete pool systems that free from you the constant worry and work of normal pool maintenance. But with the flow switch right under the cell I don't think you have room for that. Cleaning Tool: This component is unique to the CircuPoolSJ Series and allows for simple acid-free maintenance of the Cell. Remember that your pool is compatible with chlorine and shock as normal. will this fit the sj-15 You would want to simply check whether on your lowest speed the salt system 1) stays filled with water, and 2) the flow switch gets triggered. View Details Add The Vertical Installation kit does not come with the flow switch or cell. View Details Add To Cart (12) CircuPool® RJ Keypad (3rd Gen, RJNK16) $58. RJ PLUS The two conditions are likely unrelated, but first you should remove your flow switch and verify that there is no debris caught up in the switch and that there is no obvious physical damage to the switch. To correct this, you'll need to adjust the position of the jumper within the control module. Page 14: How To Install The Flow Switch CircuPool Help Guides: Universal / Si Series How to Install the Flow Switch WARNING ALWAYS MAKE SURE THE INPUT POWER IS COMPLETELY DISCONNECTED BEFORE ATTEMPTING How to Install the Temperature Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. --> The question is, when I am at the low speed I suspect the flow will not be enough for the flow switch to read so it will not produce salt. Activity timeframe - Apply filters ; Questions ; Most Popular Recently Absolutely, the CircuPool RJ PLUS Series of Salt Chlorinators provides the flexibility to install the flow switch in a vertical position, either before or after the salt cell, based on your specific requirements. does the rj45 come with a flow switch? CircuPool® RJ-60 PLUS Salt Chlorine Generator RJ PLUS Series Status: Open May 11, 2023 - 11:45 AM. WARNING - ALWAYS MAKE SURE THE INPUT POWER IS COMPLETELY DISCONNECTED BEFORE Circupool RJ30 Installation And Operation Manual (24 pages) Saltwater chlorination system, advanced swimming pool sanitation. CircuPool® Flow Switch with 15' Cable (No Tee Fitting) $79. CircuPool SJA Flow Switch (without PVC T-Fitting) $78. EXCELFU Flow Switch for Hayward Goldline Salt Chlorine Generator System, Pool Flow Sensor for Hayward Salt Cell Aquarite, Flow Switch Assembly GLX-FLO-RP with 15-Feet Cable 4. Learn; Cart 0; Menu; Account; Live Help; SALE: Upgrade to next larger size for $10 - Year End Event Your Salt Pool System Experts. Asked 6 ´months ago | Support. Damage from animals or landscaping equipment could cause this. A: The Flow Switch for a CircuPool SJ-A Series Salt Chlorinator should be installed, as should the Salt Cell, after everything the water flows through - commonly the pump, filter, and heater - before returning to the pool. 2. This part replaces a standard Flow Switch and includes a temperature sensor, which can be used if accurate temperature readings are no longer being provided by the Cell. Remember that the flow switch has to be installed so that the water will push that toggle closed. Status: Open Oct 06, 2022 - 10:11 AM. May 05, 2021 - 12:00 AM Inspect flow switch wire for any abrasions or cuts to make sure that is not where the issue lies. I am replacing my SGS 540 control panel, but I do not want to have to add the flow switch to the plumbing, since the chlorinator automatically switches off when the pump does. Do you have the same question? Follow this Question. Make sure the paddle moves back and For the CircuPool DJA Series of salt chlorinators, it is important to understand that the flow switch is a necessary part of the system and must be installed and connected. 6 are within CircuPool® SJ-20 Salt Chlorine Generator Q&A. Ask your question here Home; Login; Register; Search My system does not use a timer, can the RJ45 rely on the flow sensor to switch on and off? RJ PLUS Series Status: Open May 03, 2024 - 12:07 PM. Ordered this to replace my Circupool flow switch. If your pool is Asked 1 ´year ago | CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) Can I install flow switch vertically before cell if cell is installed horizontally? View answer. Getting Started Ideal Salt Level & Pool Size Installing the Electrolytic Cell and Flow Switch Wiring Troubleshooting. View Details Add To Cart (3) CircuPool® CORE Adapter Kit - for existing Hayward® Salt Cell Plumbing. Yes, that is correct. The UL40 is a powerful unit with a long warranty - a favorite for the Do-It-Yourself crowd. $39. 99. Will this stand work with this set up? View answer. But then I read threads about the desirability of having an alternative to making sure the Yes, and you can also easily replace the flow switch by unscrewing it from its pvc T-fitting and xxxx the new one in place. However, they do offer options for controlling chlorine production. Where can I get a replacement temperature flow switch Status: Open Jul 30, 2024 - 07:12 AM. Flow Switch Housing-PVC housing for generic flow switch. Ask your question here Home; Login; Register ; Search i need flow switch only, not the pvc fitting. Will this fit model S160? Serial no 05aa5da3f50037 View answer. Display View answer. View More Product Details . Aug 07, 2024 - 12:58 PM . In Stock. Availability: In Stock. 1. Does the generator need to be on a timer also or is it ok to just let the flow switch shut down the unit when the pump is off? CircuPool® RJ-45 PLUS Salt Chlorine Generator RJ PLUS Series Status: Open Jul 26, 2022 - 12:00 AM Installing the Electrolytic Cell and Flow Switch 14 Installing the Control Module 15 Connecting to Power 15 Installation Checklist 17 HELPFUL HINTS 18 TROUBLESHOOTING 19 WARRANTY 21. However, both components should be installed in such a way that they are the final stages the water passes through prior to reentering the pool. Using its available adapter kit, the EDGE Series will replace Hayward® Aqua Rite® systems without cutting or gluing, making it a snap to upgrade your salt pool system!* How to Set the Temperature Reading Source for the Temperature Flow Switch WARNING If a flow switch is replaced by a “temperature / flow switch”, follow these instructions to allow the electronics to take temperature readings from the sensor in the new temperature / flow switch. Replace the original flow switch. View Details Add To Cart (35) CircuPool® Cleaning Stand for CircuPool RJ Plus, Universal, and Si Systems. Flow is getting reduced due to an external Absolutely, the CircuPool RJ PLUS Series of Salt Chlorinators, including the RJ-45 PLUS model, provides the flexibility to install the flow switch in a vertical position, either before or after the salt cell, based on your specific requirements. Warranty Guide. Turn the top 1 day ago · A: The CircuPool EDGE Series Salt Chlorinator's Flow/Temperature Sensor PVC T-Fitting is designed to fit 2" PVC pipe. Is the flow switch required on a salt chlorinator system? View answer. CircuPool® SJ Adapter Kit (from existing RJ-Classic Models) $15. This flow switch is only compatible with 2nd generation SJ-A salt chlorine CircuPool SJA Flow Switch (without PVC T-Fitting) SJ-Classic Models Status: Open Jul 30, 2022 - 12:00 AM. testing a salt cell View answer. $3. Thank you for your question. 5hp pump CircuPool® Classic Combo (Salt Chlorinator + Pump) SJ Series Status: Open May 05, 2021 - 12:00 AM. Mar 25, 2021 - 12:00 AM. Ask a question. 866-766-5243; Live Chat; Account Cart 0. Browse CircuPool EDGE Flow Switch (without PVC T-Fitting) questions and answers, or ask your own CircuPool EDGE Flow Switch (without PVC T-Fitting) question and receive a knowledgable answer from a topic expert. Asked 1 ´year ago . Asked 1 ´year CircuPool EDGE Flow Switch (without PVC T-Fitting) $68. Mar 21, 2024 - 01:47 PM. If after checking these things you need to troubleshoot, please call our support line at 888-206-9938 x2 Inactive unit, flow switch not triggered Inspect Flow Switch, verify sufficient water flow Inactive unit, power is off Turn on system, or see “No Power” Low or no Chlorine residual in pool after recent installation Water chemistry was not balanced prior to system installation and a high chlorine demand persists CircuPool® Flow Switch with 15' Cable (No Tee Fitting) $79. Read and follow all instructions. Page 25 Wiring (Continued) The Control Module comes with an un-terminated Power Cord (AC Input) which is typically connected to an external timer, which will turn the pump and Control Module on and off together. Disconnect the flow switch wire from the Si control box. what is the minimum or recommended flow rate and what RPM speed with that be on a 1. Control Module: This component supplies power to the cell and allows you to customize the system's operation in order to meet your pool's Can the flow switch be installed vertically while the CORE will be horizontal? View answer. I purchased the Vertical installation kit but it does not include a flow switch housing. CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) . CircuPool EDGE Flow Switch (without PVC T-Fitting) $68. Engineered to the Also allows for easy conversion from Circupool RJ Classic models. Oct 24, 2023 - 06:43 Asked 2 ´years ago | CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) My sj45 was made in 2020 can I still purchase a replacement cell? View answer. Pump RPM and duration is 100% unique to the way your pool equipment is set up and the needs of the pool. Many CircuPool RJ-PLUS Series Salt Chlorinator owners who do not utilize timers, rely on the system's Flow Switch to start and stop chlorination. Status: Open Dec 13, 2022 - 11:24 AM. CircuPool SJA Flow Switch . Absent any marking or indicator, if the system does not report a “No Flow” condition, then the cell is oriented CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) Can I order just the flow sensor w/out the PVC-T? Just the flow sensor has failed. Temporarily, without the new switch, the CM adjustment allows the chlorinator to function at a default Yes, indeed. NOT COMPATIBLE with: Hayward Aqua Rite, CircuPool Si, CircuPool RJ (3rd-gen. Q: Hello, I have just purchased the RJ The CircuPool RJ-PLUS Series Salt Chlorine Generators, including the CircuPool RJ45, don't have in-built programmability. says water temp is 46 degrees and my Jandy says its 78 deg CircuPool RJ-PLUS Series Salt Chlorine Generators - Owner How to Install the Temperature Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. Q: if cell maintenance light flashes like a strobe light instead My current setup has the flow switch positioned 5-6" AFTER the cell in a horizontal run. Install new flow switch and twist it clockwise to tighten. 49. As such, I'm wondering where the flow switch electrical connection/wire would connect. My RJ PLUS control module is reading 0 amps; it's not generating chlorine. Can a circupool core When installing the CircuPool® RJ-60 PLUS Salt Chlorine Generator, it's important to note that the RJ-Plus series salt chlorinators require at least 6" of pipe before the 4" flow switch housing. I need a new flow switch for my RJ-30 Circupool salt system. Flow Switch: This component ensures that there is adequate water flow for the Cell to activate. Unscrew the flow switch from the PVC “T CircuPool Help Guides: ( Gen. This guide will help visualize the steps of plumb Typically a low flow rate of 20-30 GPM is needed to provide sufficient water flow. This item includes the Flow Switch and its 15' cable. Tools Required: Hack-saw or PVC cutter; PVC primer and PVC cement; Measuring Tape. It also contains additional sensors that ensure optimal operation of the Cell. Please let us CircuPool® Flow Switch with 15' Cable (No Tee Fitting) $79. Since the cell is clear this is very easy to check. Can I install flow switch vertically before cell if cell is installed horizontally? View answer. Took the chance that this would be a direct fit and would work. Will this product bypass my Hayward W3T-CELL-15 TurboCell Salt Chlorination Cell? View answer. Can I use a RJ-45 plus replacement cell with it? View answer. Ask your question here Home; Login; Register; Search CircuPool® Flow Switch with 15 Q&A. I recently purchased a variable speed pump which leaves the unit on displaying various lightsI realize the flow switch controls the Cell but I dont want to unnecessarily damage the unit by leaving it powered 24-7 View answer. View Details Select Options (8) CircuPool® O-Ring Set for RJN/UL/Si . Ask your question here Home; Login; Register; Search Why does my display say "LOW TEMP" and not generating. Contact Us. We are also happy to help you if you give our support team a call at 888-206-9938. Anything installed between the Flow Switch and the Salt Cell, such as a Heater, could possibly impede water flow just enough to create what would otherwise be a "No Flow" condition and potentially damage the Salt Chlorinator. Status: Open Oct 24, 2023 - 06:43 AM. These components are made Oct 6, 2022 · As an installation suggestion, most instructions will recommend that the flow switch be given 6-12" of straight piping before the flow switch (the salt cell can count for this), so as to ensure that water flow is consistent as it enters the Browse CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) questions and answers, or ask your own CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) 1 day ago · Standard Flow Switch, fits Hayward Aqua Rite, CircuPool Si/Universal, CircuPool RJ (3rd-gen. The CircuPool® Flow Switch / Temperature Sensor, designed for the RJ Plus Series of Salt Chlorinators, features a temperature sensor. × . We understand your concern about your CircuPool Universal Series Salt Chlorine Generator displaying a "Hot" message. View Details Add To If necessary, you can install the Flow Switch right after the Cell. If the pump must be Flow Switch & Temperature Sensor: This component ensures that there is adequate water flow for the Cell to activate. Result (B): No Flow light turns off; flow switch does NOT need to be replaced. View Details CircuPool EDGE Flow Switch (without PVC T-Fitting) $68. Turn the top of the Flow Switch counter clockwise until the switch is loose enough to pull out of the PVC fitting. $12. For optimal results, allow a few extra inches on each side or between fittings. ), CircuPool Universal, or other similar style flow switches. 5” threaded cell unions, Flow Switch, mounting bracket and associated hardware, and instruction manual. I have a variable speed pump. Current item availability is displayed on the product page. Replacement Cartridges. View Details Add To Cart (1) CircuPool EDGE Temperature Sensor (without PVC T-Fitting) $29. • Arrange equipment and fittings according to the illustration. Circupool SJA flow sensor compatibility CircuPool SJA Flow Switch (without PVC T-Fitting) SJ-Classic Models. Install new flow switch and twist it clockwise to tighten When the no flow light is on, this typically means either the flow switch is not being triggered by the water, is not installed correctly, is not connected, or other related issue. I have an RJ-60+ which is rated at 300W, so presumably it only draws 1. The CircuPool manual noted it was fine to use the flow switch to determine whether the SWCG was powered or not. View answer. 1 answer. Great news! It is acceptable to position the flow switch after the salt cell . Will this part fit? View answer. CircuPool SJA Flow Switch; Sale. 6 are within • Verify that water flow is sufficient to fully press the Flow Sensor paddle away from its resting center position. If the flow switch sensor or its wire is damaged or needs to be replaced, it can be unscrewed from its current fitting and a new flow switch can be screwed in place. 0 . The CircuPool RJ-45 PLUS uses advanced Extended-Lifespan How to Install the Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. Mine is 17,000 and it doesn’t keep my pool clean. 00. × All Q&A. Replacement Lamps. Jul 30, 2024 - 07:12 AM. Is this compatible with SJ models? Status: Open Nov 10, 2022 - 07:05 AM. CircuPool® O-Ring Set for SJA Union Ports. All troWARNING: ubleshooting procedures should be done by a qualified professional. Have had a Century V-Green 165 pump motor for a number of years. Nov 17, 2022 - 08:53 AM. Since the CORE's flow switch is located inside the clear housing with the salt cell, it will, necessarily, be installed horizontally as well. Filter. Dec 13, 2022 - The CircuPool CORE Series of Salt Chlorinators should only be installed horizontally. Complete Equipment Package Deals. In case you have a variable speed pump, increase flow until the LED turns off. 3 out of 5 stars 131 1 offer from $2199 $ 21 99 The CircuPool SJ20 uses advanced titanium electrolytic cells to effortlessly and automatically maintain sparkling blue water for a luxurious swimming experience. However, to correct temperature readings, you must adjust the Control Module (CM), as demonstrated in this video. CircuPool® Classic Combo (Salt Chlorinator + Pump) CORE Series Status: Open Mar 25, 2021 - 12:00 AM. $22. Just started recently, when the unit first turns on, it hums and vibrates. Follow the provided Inactive unit, flow switch not triggered Inspect Flow Switch, verify sufficient water flow Inactive unit, power is off Turn on system, or see “No Power” Low or no Chlorine residual in pool after recent installation Water chemistry was not balanced prior to system installation and a high chlorine demand persists Circupool CircuPool® Universal25 Saltwater Chlorinator - Complete System with 25k-Gallon Max Titanium Cell & 4 Year Warranty Rinoson Smart Saltwater Pool Chlorinator System with Five Year Warranty-App Remote Control & Titanium Plate Self-Cleaning WiFi Salt Chlorine Generator for Pools up to 22,000 Gallons flow switch wire is broken, only need switch. Additionally, the cell itself is 14" long. In-stock items typically ship within 1 business day, and UPS ground transit time is CircuPool® SJ-45 Salt Chlorine Generator SJ Series. - Ideally they recommend 12 inches of straight run for the flow switch if not on the same line as the cell A: Yes, this model has a flow switch that helps ensure it runs in sync with a programmable VS pump. That means is you may have to keep the VSP at a more moderate rpm if a low speed doesn't keep the plates covered in water enough to operate properly. Comments (0) | New Comment. Comments (0) | New This configuration allows the Electrolytic Cell and Flow Switch to be installed in your pool plumbing while taking up a minimal amount of space. Comments (0) | New Comment . With a CircuPool RJ PLUS Series Salt Chlorinator, it is normal for the flow light to flash initially for as Is the flow switch required on a salt chlorinator system? View answer. RJ Series 3rd ) Always make sure that input power is completely disconnected before attempting service or troubleshooting procedures. Our tech support team is happy to help you troubleshoot at 888-206-9938 ext:2. This part is threaded into How to Install the Temperature Flow Switch Installation Steps for installing a Flow Switch into existing equipment: 1. Install new flow switch and twist it clockwise to CircuPool® Flow Switch with 15' Cable (No Tee Fitting) $79. Status: Open Nov 17, 2022 - 08:53 AM. When it will go CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) RJ-PLUS Models. flow switch wire is broken, only need switch. Jun 07, 2021 - 12:00 AM 2 . Your Name or Alias: * Email: * (Your email will not be displayed) Q:: Provide your Answer: * What's your question?: * Close Submit your Question Answer it. Worried about the unit coming on via the old pool timer without the new pump running? CircuPool® Classic Combo (Salt Chlorinator + Pump) SJ CircuPool® Flow Switch / Temperature Sensor (No PVC Tee Fitting) Status: Open Jul 19, 2022 - 12:00 AM. CircuPool RJ-PLUS Series Salt Chlorine Generators - Owner Resources. View Details Add To Cart (1) CircuPool® Threaded Cell Collar - Universal / Si Series. View Browse CircuPool® Flow Switch with 15 questions and answers, or ask your own CircuPool® Flow Switch with 15 question and receive a knowledgable answer from a topic expert. wwx xugt mltvwo ugiekrj savl phwn awrpiyvg yozgdde wjlgdlv kur